Becker rotary vane vacuum pump
Models: VT 4.16, VT 4.25, VT 4.40, KVT 3.60, KVT 3.80, KVT 3.100, KVT 3.140, VTLF 2.250
m³/h-intake air flow | |||||||||||
kPa Absolute | 100 | 90 | 80 | 70 | 60 | 50 | 40 | 30 | 20 | 15 | 10 |
kPa Relative | 0 | -10 | -20 | -30 | -40 | -50 | -60 | -70 | -80 | -85 | -90 |
50 Hz VT 4.16 60 Hz |
16 19 |
15.7 18.6 |
15.3 18.2 |
14.9 17.6 |
14.2 16.8 |
13.2 15.6 |
11.8 14.0 |
9.4 11.2 |
4.7 5.6 |
0.1 0.1 |
|
50 Hz VT 4.25 60 Hz |
25 30 |
24.5 29.4 |
23.9 28.7 |
23.1 27.7 |
22.1 26.5 |
20.6 24.7 |
18.4 22.1 |
14.7 17.6 |
7.4 8.8 |
0.1 0.1 |
|
50 Hz VT 4.40 60 Hz |
40 48 |
39.2 47.1 |
38.2 45.9 |
37.0 44.4 |
35.3 42.4 |
32.9 39.5 |
29.4 35.3 |
23.5 28.2 |
11.8 14.1 |
0.1 0.1 |
|
50 Hz KVT 3.60 60 Hz |
55 66 |
55 65 |
54 64 |
53 63 |
52 61 |
50 59 |
48 55 |
45 49 |
37 37 |
20 25 |
0.1 0.1 |
50 Hz KVT 3.80 60 Hz |
67 78.5 |
66 77 |
65 76 |
63 75 |
61 73 |
59 70 |
55 65 |
49 58 |
38 44 |
24 29 |
0.1 0.1 |
50 Hz KVT 3.100 60 Hz |
98 112 |
97 111 |
96 109 |
93 107 |
90 104 |
86 100 |
80 93 |
71 83 |
56 62 |
35 41 |
0.1 0.1 |
50 Hz KVT 3.140 60 Hz |
129 154 |
127 152 |
125 150 |
123 147 |
120 143 |
116 138 |
108 130 |
96 117 |
75 90 |
47 | 0.1 |
50 Hz VTLF 2.250 60 Hz |
244 286 |
242 284 |
238 281 |
235 276 |
230 270 |
222 261 |
210 248 |
197 230 |
165 195 |
Learn about our latest products and discounts through SMS or email